Draeger PAC 8500 O2/CO-LC

SKU DS-8328265
(0) No Reviews yet
$849.99

Details

Draeger PAC 8500 O2/CO-LC

*Used by FDNY*

The Draeger PAC 8500 single-gas detection device is a reliable and precise instrument even under the toughest of conditions. The detector can be equipped with a hydrogen-compensated CO sensor or a Draeger dual sensor. The dual sensors provide the option of measuring two gases at once: either H2S with CO or O2 with CO.

Strong performance for maximum safety
You can count on the Draeger PAC 8500 to give you reliable, precise readings at any given time even under extreme conditions. Our powerful sensors with a low t-90 response time ensure quick reactions. In addition to the standard alarms, you can define extra alarm thresholds for TLV and STEL

The PAC 8500 also provides a data and event logger concentrations and events along with the date and time. The data can be loaded on a PC via an interface and processed further there.

Two gas detection in a single device
The Draeger PAC 8500 series offers the following sensor combinations: hydrogen sulfide with carbon monoxide or oxygen with carbon monoxide. Dual sensors enable detection of even low concentrations - all in one and the same handy device. Measuring two gases at the same time reduces downtime as well. You can take vol. % measurements of oxygen and ppm measurements of carbon monoxide simultaneously using just one gas detector.

Measurement of carbon monoxide with significantly reduced cross sensitivity 
In industries where carbon monoxide needs to be measured with hydrogen as a background gas, the measured value for carbon monoxide may be falsified by cross sensitivity. Thanks to the special hydrogen-compensated CO sensor from Draeger, this cross sensitivity to hydrogen is significantly reduced in the display of carbon monoxide. This new feature can eliminate the need to carry two different detectors.

Robust design - even for the toughest conditions
The PAC 8500 is easily handled in even extreme conditions. The sensors can tolerate air pressures between 700 and 1,300 mbar. A membrane filter protects the sensor from foreign matter such as dust and liquids. The shock-proof, chemical resistant housing meets the requirements specified in the IP68 standard rating.

Easy handling thanks to clear user guidance
The D-light indicates whether functionality of the device has been tested and if it is ready to use. The housing is also designed with your safety in mind: each sensor variant of the Draeger PAC 8500 features clearly visible color coding, thereby minimizing the chance of mistakes.

User-friendly display with all important information
The large display is word-free and clearly indicates the respective gas concentration. Other important information, such as the unit of concentration and battery capacity, is also displayed. The bright backlighting ensures that all values are clearly legible in the dark.


360 Degree alarm with various functions
All of the versions of the Draeger PAC 8500 are equipped with extremely durable DraegerSensors and a powerful battery.

The PAC 8500 is protected against water, dust and other foreign bodies by a special membrane filter. When the filter becomes heavily soiled in use, you can quickly and easily replace it yourself. The detector is then ready to use again right away. Thanks to the powerful battery, the PAC does not require charging on a daily basis and is easy to handle.

Fast function test saves time and money
Function tests and calibrations can be carried out especially efficiently in the Draeger X-dock calibration station. The automatic bump tests in the X-dock are a cost-efficient and convenient solution thanks to the short test duration and the extremely low consumption of test gas. The PAC 8500 is simply placed in the bump test station and automatically selects the correct setting.

Specifications

  • Dimensions: 2.5" x 3.3" x 0.8"
  • Weight: Approx 3.7 oz
  • Battery Service Life: Min 2 years
  • Protection Class: IP68
  • Air Pressure: 700 to 1,300 hPa
  • Air Humidity: 10 to 90% relative humidity, non-condensing
  • Temperature: -22°F - 131°F
  • Approvals: cCSAus, IECEx, ATEX, CE