PGI Cobra Classic Carbon Shield Firefighting Hood

SKU PGI-30200-00-192098
(0) No Reviews yet
$39.65

Details

PGI Cobra Classic Carbon Shield Firefighting Hood

Cobra™ Classic™ hoods provide double layer coverage of neck, upper chest and top of the shoulder blades. The notched side helps bib lie flat for improved interface with bunker coat. Flat-stitched seams eliminate bunching and won’t dig into skin. A half inch wide elastic face opening stretches to full 17" to ensure a snug fit around most SCBA masks. UL Classified to NFPA 1971 Standard on Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting – Current Edition.

Fabric Description:
Considered the ultimate high-tech fabric for thermal protection and comfort. The Carbon Shield™ fabric simply won’t burn in air. Additionally, this fabric has excellent moisture regain and wicks moisture away from the skin to the outer shell enabling it to evaporate at a rapid rate.

Features:

  • Double layer coverage of neck, upper chest and top of the shoulder blades.
  • Length top to bottom, front to back bib approximately 19".
  • Shoulders are contoured to reduce bunching at neck and bib.
  • Bib length from below face opening is 10½".
  • UL Classified to NFPA 1971 Standard on Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting — Current Edition.

Specifications

Test Results:

Thermal Protective Performance (TPP):

  • As Received: 31.2 minutes
  • After 5 Washings: 33.1 minutes


Hood Material Burst Strength: 411 N

Flame Resistance Test

  • After Flame (Wales x Courses) As Received: 0.0 sec x 0.0 sec
  • After Flame (Wales x Courses) After 5 Washings: 0.0 sec x 0.0 sec
  • Char Length (Wales x Courses) As Received: 0 mm x 0 mm
  • Char Length (Wales x Courses) After 5 Washings: 0 mm x 0 mm


Cleaning Shrinkage Resistance Test

  • Hood Measurement After 5 Washings: -1% to 0.3%


Heat & Thermal Shrinkage Resistance Test

  • Hood Measurement As Received: -1.4% to 0.0%
  • Hood Measurement After 5 Washings: 0.0%


Limited Oxygen Index (LOI): 43

Seam Breaking Strength Test: 630 N

Melt or Drip When Exposed to Flame: NONE

Arc Thermal Performance Value (ATPV): 32 cal/cm^2

NFPA 70E Hazard Risk Category (HRC): HRC 3

Ratings & Reviews

No reviews available

Be the first to Write a Review

Videos

Size Chart

Training Materials