PGI Elite Para-Tek FR Tri-Blend Firefighting Hood
Details
PGI Elite Para-Tek FR Tri-Blend Firefighting Hood
Cobra™ Elite™ hoods offer improved styling for better fit and maximum coverage. Hoods provide double layer coverage of neck, upper chest, shoulders and shoulder blades. The tapered back and notched shoulder drape allow bib to lie flat for a more comfortable fit. Flat-stitched seams eliminate bunching and won’t dig into skin. A half inch wide elastic face opening stretches to full 17" to ensure a snug fit around most SCBA masks. UL Classified to NFPA 1971 Standard on Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting – Current Edition.
Fabric Description:
PGI's proprietary tri-blend of Lenzing FR®, high strength para-aramid and high tenacity nylon. This superb flame resistant fiber combination offers an outstanding TPP rating, arc flash protection and excellent moisture absorbency.
Features:
- Longer length front and back for maximum coverage.
- Double layer coverage of head, neck, chest and shoulder blades.
- Tapered back and notched shoulder design to help bib lie flat on both chest and back.
- Length top to bottom, front to back approximately 20½".
- UL Classified to NFPA 1971 Standard on Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting — Current Edition.
Specifications
Test Results:
Thermal Protective Performance (TPP)
- As Received: 32.7 minutes
- After 5 Washings: 31.5 minutes
Hood Material Burst Strength: 476 N
Flame Resistance Test
- After Flame (Wales x Courses) As Received: 0.0 sec x 0.0 sec
- After Flame (Wales x Courses) After 5 Washings: 0.0 sec x 0.0 sec
- Char Length (Wales x Courses) As Received: 42 mm x 44 mm
- Char Length (Wales x Courses) After 5 Washings: 28 mm x 41 mm
Cleaning Shrinkage Resistance Test Hood Measurement After 5 Washings: -1.0% to -0.7%
Heat & Thermal Shrinkage Resistance Test
- Hood Measurement As Received: -1.4% to 0.0%
- Hood Measurement After 5 Washings: -0.4% to 0.9%
Limited Oxygen Index (LOI): 31
Seam Breaking Strength Test: 789 N
Melt or Drip When Exposed to Flame: NONE
Arc Thermal Performance Value (ATPV): 33 cal/cm^2
NFPA 70E Hazard Risk Category (HRC): HRC 3
Ratings & Reviews
No reviews available