Draeger X-am 8000 PID/LEL/CO/O2/H2S

SKU DS-8325800
(0) No Reviews yet
$5,971.99

Details

Draeger X-am 8000 PID/LEL/CO/O2/H2S

*Used by the FDNY*

Clearance measurement was never this easy and convenient: The 1 to 7 gas detector detects toxic and flammable gasses as well as vapors and oxygen all at once - either in pump or diffusion mode. Innovative signaling design and handy assistant functions ensure complete safety throughout the process. 

Specifically designed for use with a pump, optimized for clearance measurement 
The Draeger X-am 8000 is equipped with a very powerful pump. It can be connected with hoses of up to 148 feet in length. A pump adapter makes it easy to switch between diffusion and pump mode at any time. This means the pump is only operated when you actually need it. That saves energy, reduces wear and tear, and extends the lifespan of the pump.

Handy and durable, the Draeger X-am 8000 is intuitive to operate single-handedly using three function keys. The easy-to-read color display clearly lays out all the information for you.

The multi-gas detector also features advanced software functions including change of measurement gas for PID, CatEx, and IR sensor during operation. This is based on an on-board library and a convenient assistant to hide unused sensor channels and adapt the flexible instrument to the measurement task.

Standard accessories include a sturdy shoulder strap so you can comfortably carry the X-am 8000. Thanks to its compact and robust construction, the device can withstand even the harshest conditions.

Clearance measurement, release and documentation in no time
The X-am 800 effectively supports various applications with specially developed assistant functions that guide you through each process step by step. During clearance measurement, for example, the smart assistant calculates the necessary flooding time for the device and probe (FKM Hose) based on parameters such as measuring gases, temperature limits, and the indicated hose length. Additionally, customer defined flooding times are also possible. 

When monitoring for potentially high methane concentrations, an optional automatic measurement range switch makes it easier to take a reading: If the Cat-Ex sensor measures values above 100% LEL, the display switches to the range of 0 to 100 % vol %. A similar function to measure in % LEL and vol % simultaneously is also available for the IR EX ES sensor.

Clear Signaling Design
The signal system of the Draeger X-am 8000 is based on a clear color code, in accordance with the requirements of EN 60079-29-1, EN 45544-1 and EN 50104: 

- Red Light = Gas alarm
- Yellow Light = Device-related alarm, ex. Low battery
- Green Light = Device is ready for use

The green glow of the D-light allows you to see from a distance whether the device has been properly tested and is ready for use.

In case of an alarm, the X-am 8000 alerts you with colorful warning LEDs, a loud horn (100 dB) and clearly palpable vibration. Optionally, four preset hazard symbols are available for the display which explicitly indicate the presence of explosive or toxic gas hazards, for example. This allows the user to easily recognize the type of hazard based purely on the symbol displayed.

The X-am 8000 is equipped with an impact detection system. The event report indicates whenever severe mechanical impacts have occurred that might result in functional impairments of the device or the sensors. These are also documented in the data logger. With this information, a device operator can specifically check the device. The instrument can also be locked after a detected impact as well.

Economical fleet management 
Bumptest and calibration are carried out simply and quickly using the Draeger X-dock calibrating station. Its low test gas consumption keeps operating costs a minimum. 

Specialist for high and low hydrocarbon concentrations
To measure hard-to-detect hydrocarbons, you can fit the Draeger X-am 8000 with one of two high-performance PID sensors. The PID HC covers a measurement range of 0 to 2,000 ppm (isobutane). The PID LC ppb is particularly suited for a measurement range of 0 to 10 ppm (isobutane) with a high resolution in the range below 1 ppm.

For benzene-specific measurements, the X-am 8000 can be used with a pre-tube.

Inductive charging protects against wear and tear
The X-am 8000 features inductive charging. This makes it easier to operate and increases the lifespan of the device. Issues like corrosion and contact problems in the charging cradle are a thing of the past. You can charge (outside of explosion-hazard zones) and measure at once.

Specifications

  • Dimensions: 179 x 77 x 42 mm
  • Weight: Aprox 500 g 
  • Housing: Durable two-component housing
  • Display: High-contrast color display
  • Temperature: -4°F - 122°F
  • Pressure: 700 to 1,300 hPa (measuring function), 800 to 1,100 hPa (use in explosion-hazard areas)
  • Relative Humidity: 10 to 90% 
  • Visual Alarm:3 LED's 'red' (gas-alarms), 3 LED's 'yellow' (device alarms)
  • Acoustic Alarm: Multi-tone, typically 100 dB(A) at 30 cm
  • Ingress Protection Class: IP68
  • Energy Supply: Lithium-ion battery, rechargeable, inductive charging
  • Charging Times: Typically 4 hours
  • Start-up times: Typically 1 minute
  • Data Storage: 24 MB, e.g. at 10 minutes per hour of gas exposure with measuring values changing by the second on all 7 channels: aprox. 400 hours
  • Pump Operation: Max hose length 45m
  • Approvals: ATEX, EAC, cCSAus, ANZEx