PGI Cobra Ultimate Carbon Shield Firefighting Hood
Details
PGI Cobra Ultimate Carbon Shield Firefighting Hood
Cobra™ Ultimate™ hoods are double ply and feature extra-long length that covers head, chest, shoulders and shoulder blades for enhanced protection. Flat-stitched seams eliminate bunching and won’t dig into skin. A half inch wide elastic face opening stretches to full 16" to ensure a snug fit around most SCBA masks. UL Classified to NFPA 1971 Standard on Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting – Current Edition.
Fabric Description:
Considered the ultimate high-tech fabric for thermal protection and comfort. The Carbon Shield™ fabric simply won’t burn in air. Additionally, this fabric has excellent moisture regain and wicks moisture away from the skin to the outer shell enabling it to evaporate at a rapid rate.
Features:
- Designed for maximum protection.
- Double layer coverage of head, neck, chest and shoulder blades.
- Gusset at side seams add additional coverage at top of shoulders and is patterned to reduce bib from bunching in front and back.
- Bib length from below face opening is 12½".
- Length top to bottom, front to back approximately 21½".
- UL Classified to NFPA 1971 Standard on Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting — Current Edition.
Specifications
Test Results:
Thermal Protective Performance (TPP)
- As Received: 31.2 minutes
- After 5 Washings: 33.1 minutes
Hood Material Burst Strength: 411 N
Flame Resistance Test
- After Flame (Wales x Courses) As Received: 0.0 sec x 0.0 sec
- After Flame (Wales x Courses) After 5 Washings: 0.0 sec x 0.0 sec
- Char Length (Wales x Courses) As Received: 0 mm x 0 mm
- Char Length (Wales x Courses) After 5 Washings: 0 mm x 0 mm
Cleaning Shrinkage Resistance Test Hood Measurement After 5 Washings: -1.0% to 0.3%
Heat & Thermal Shrinkage Resistance Test
- Hood Measurement As Received: -1.4% to 0.0%
- Hood Measurement After 5 Washings: 0.0%
Limited Oxygen Index (LOI): 43
Seam Breaking Strength Test: 630 N
Melt or Drip When Exposed to Flame: NONE
Arc Thermal Performance Value (ATPV): 32 cal/cm^2
NFPA 70E Hazard Risk Category (HRC): HRC 3
Ratings & Reviews
No reviews available
Be the first to Write a Review