Key Fire Hose BIG-10 Double Jacket Fire Hose All-Polyester Rubber Lined Attack Hose with Aluminum Couplings

SKU KFH-DP10-800
(0) No Reviews yet
$160.99 to $688.99
$160.99 to $688.99

Details

Key Fire Hose BIG-10 Double Jacket Fire Hose All-Polyester Rubber Lined Attack Hose with Aluminum Couplings

**If you do not see a spec listed, please contact us to order**

 

The standard in double jacket construction, combining 100% premium ring spun and filament polyester fibers over a heavy wall, ozone resistant, EPDM rubber liner. The outer jacket is mildew resistant and available with our iconic "Key-Lok" polyurethane based polymer impregnation for maximum abrasion and moisture resistance.

 

Rugged, easy to handle and preferred by metro cities across the US and Canada — available in exclusive FDNY Spec with 1.88" inside diameter and heavier construction with a 1-year all hazards warranty.

 

This reliable, double jacket fire hose is UL Listed*, tested to 600 and 800 psi and meets MIL-H-24606 latest edition for abrasion resistance.

 

Features a 10-year warranty and lifetime liner delamination guarantee.

 

Scope:

Hose manufactured to this specification shall be of superior quality and workmanship. The hose shall withstand the rough usage of front line fire fighting. Hose specified shall meet NFPA 1961 standards. Hose furnished under these specifications will have a potential service life and warranty of 10 years with a lifetime warranty against liner delamination, barring mistreatment that would render it unfit for service. FDNY Spec hose also carries a 1-year all hazards warranty. Upon delivery, the hose shall be free from defects in materials and workmanship.

 

Jacket Construction:

Double jacket hose manufactured to this specification shall be tightly woven with filament polyester yarn in the filler and ring spun polyester yarn in the warp of both the inside and outside jackets. Inside jackets manufactured from 100% filament polyester would not meet Big-10 minimum standards. The hose shall be resistant to most chemicals and petrol products, and resist deterioration due to exposure to UV rays and ozone. It shall not be affected by rot or mildew. The inside and outside jackets shall be manufactured with a minimum pick count of 9.5 picks per inch for increased strength and abrasion resistance. The inside jacket shall be manufactured using a reverse twill process to reduce friction loss. The inside jacket shall be manufactured on a circular loom in a clockwise direction and the outside jacket in a counter-clockwise direction. The hose must be of sufficient body and weight to meet the demands of heavy-duty fire fighting usage.

 

Abrasion:

Hose assemblies shall be available with the special "Key-Lok" polyurethane based polymer impregnation for added abrasion resistance and ease in identification purposes. Impregnated hose shall meet the requirements of MIL-H-24606 latest edition for abrasion resistance. NFPA colors may be specified by the end-user. A double dip process for twice the abrasion resistance is available upon request.

 

Lining:

The rubber lining shall be a single-ply extruded tube of synthetic EPDM compounded to resist ozone. The finished form shall be free of pits or other imperfections and have a smooth finish with a minimum wall thickness of .040". No reclaimed rubber shall be used. Plastic tubes that sacrifice durability of the hose life for the sake of weight are not acceptable. FDNY Lining is constructed with an ultra smooth oversized rubber liner to reduce friction loss. Tensile Strength, Ultimate Elongation and Adhesion: Shall meet the standards of Underwriters Laboratories, Inc. as well as all other properties of UL-19 for rubber lined hose. A valid UL/ULC Underwriters inspection procedure shall be in force.

 

Couplings:

Big-10 can be coupled with 6061-T6 aluminum threaded couplings or forged Storz. Special threads or other custom features available upon request. Barcode recess available at additional charge.

 

Performance:

The minimum burst test pressure, when tested in accordance to NFPA 1961, on all Big-10 diameters up to 3" shall be 1200 psi / 82 bar. Minimum burst test requirements for 31/2" diameter shall be 900 psi / 62 bar. Service test pressures stenciled on the hose shall be in accordance with current minimum requirements of NFPA 1962.
*A valid UL/ULC Underwriters 600 psi / 41 bar - 800 psi / 55 bar listing shall be in force. Lengths available up to 100'.

 

Standards:

Fire hose manufactured to this specification shall meet or exceed all performance requirements of NFPA 1961, Underwriters Laboratories and MIL-H-24606 latest edition for abrasion resistance.

 

Features:

  • Combines the rugged flexibility of filament polyester with rugged EPDM rubber liner
  • Lightweight, easy to handle and maneuver
  • Extremely durable and highly abrasion resistant
  • Mildew, chemical and UV resistant
  • 10-year warranty and guaranteed not to delaminate for the life of the hose
  • FDNY Spec hose also carries a 1-year all hazards warranty

Specifications

DiameterPart No.Service TestProof TestBurst TestBowl SizeWeight Uncoupled
1"DP10-800400 psi800 psi1200 psi138"0.14 lbs/ft
*1½"DP15-800400 psi800 psi1200 psi11516"0.34 lbs/ft
*1¾"DP17-800400 psi800 psi1200 psi218"0.38 lbs/ft
1¾" FDNYDP18-800-FDNY400 psi800 psi1200 psi2¼"0.42 lbs/ft
*2"DP20-800400 psi800 psi1200 psi225"0.31 lbs/ft
*2½"DP25-800400 psi800 psi1200 psi3"0.54 lbs/ft
*3"DP30-800400 psi800 psi1200 psi3½"0.74 lbs/ft

 

  • Double jacket construction is tightly woven with filament polyester yarn in the filler and ring spun polyester yarn in the warp of both the inside and outside jackets. Double jackets encapsulate a rubber lining consisting of single-ply extruded tube of synthetic EPDM compounded that is ozone resistant.
  • Available with a special “Key-Lok” polyurethane based polymer impregnation for enhanced color and added abrasion resistance. A double dip process for twice the abrasion resistance is available upon request.
  • Big-10 can be coupled with 6061-T6 aluminum threaded couplings or forged Storz. Special threads or other custom features available upon request. Barcode recess available at additional charge.
  • The minimum burst test pressure when tested in accordance to NFPA 1961 on all Big-10 hose up to 3" diameter shall be 1200 psi / 82 bar. Maximum burst test requirements for 3½" diameter shall be 900 psi / 62 bar. Service test pressures stenciled on the hose shall be in accordance with current minimum requirements of NFPA 1962.
  • Big-10 hose meets and exceeds all performance requirements of NFPA 1961, Underwriters Laboratories and MIL-H-24606 latest edition for abrasion resistance.

 