Solberg RE-HEALING 3X3 FLUORINE FREE SP-100 Class B Foam Concentrate
Details
Solberg RE-HEALING 3X3 FLUORINE FREE SP-100 Class B Foam Concentrate
SOLBERG® RE-HEALING™ 3x3 FLUORINE-FREE SP-100 (patent pending) foam concentrate contains cutting edge technology that is not persistent, contains no silicone/siloxane chemistries, and contains no intentionally added PFAS chemicals. SOLBERG REHEALING 3x3 FLUORINE-FREE SP-100 is designed for extinguishing and securing both Class B (hydrocarbon fuel and polar solvent fuel) and deep-seated Class A fires. This fluorine-free foam concentrate is a combination of proprietary hydrocarbon surfactants and additives delivering excellent foaming, vapor sealing, and stability properties for attacking and securing both shallow and fuel in-depth fires.
Features:
- First UL-listed fluorine-free foam for both hydrocarbon and polar solvent (water miscible) fuels using standard sprinkler heads
- UL 162 Listed
- FM-5130 Approved
- ICAO Level B
- Biodegradable and non-persistent
- Fresh, salt & brackish water compatible
- Fast knockdown & extinguishing performance tested
- Great foam stability to extended water discharge
- Excellent burnback performance
- Compatible with multiple equipment systems
- Contains no siloxanes
Applications
SOLBERG RE-HEALING 3x3 FLUORINE-FREE SP-100 is specifically designed for sprinkler applications to extinguish and secure Class B (hydrocarbon fuel and polar solvent) fuels. This technology allows it to be used successfully through both standard and air-aspirated sprinkler heads on both hydrocarbon and polar solvent fuel fires. SOLBERG RE-HEALING 3x3 FLUORINE-FREE SP-100 can also be used with low-expansion discharge devices, including a variety of nozzles and monitors. It is fully compatible and easily proportioned with standard firefighting equipment, including in-line inductors, self-inducting nozzles, fire truck pumps, bladder tanks, pump skids, balanced pressure systems, and more.
Sprinkler UL Listings & FM Approvals
SOLBERG RE-HEALING 3x3 FLUORINE-FREE SP-100 is UL 162 Listed and FM 5130 Approved for use with Solberg Hardware, Bladder Tanks, Standard Non-Aspirated Sprinklers and Foam Water Sprinklers on hydrocarbon and polar solvent fuels. For full Sprinkler UL Listing and FM Approvals, refer to Solberg Hardware – Fire Sprinklers - Technical Datasheet.
Inspection
SOLBERG RE-HEALING 3X3 FLUORINE-FREE SP-100 or a premix solution should be tested annually per National Fire protection Association (NFPA 11) and EN-13565-2 standards. A sample of the foam concentrate should be sent to the manufacturer or qualified third-party lab to confirm physical properties and foam quality meet the specifications of the foam as originally supplied as per the requirements of NFPA 11 and EN-13565-2.
Storage / Material Compatibility
SOLBERG RE-HEALING 3X3 FLUORINE-FREE SP-100 should be stored between 35°F - 120°F, preferably in the original containers. It is compatible with multiple materials of construction found in firefighting equipment. For questions about material of construction compatibility consult Perimeter Solutions technical services.
The shelf life of any foam concentrate is maximized by proper storage conditions and maintenance. Factors affecting shelf life are wide temperature fluctuation, evaporation, dilution, and contamination by foreign materials. When stored in original containers or in manufacturer-recommended equipment and within the specified temperature range SOLBERG foam concentrates have demonstrated effective firefighting performance of 10 years or greater.
Specifications
Typical Properties:
- Specific Gravity, g/cm3: (1.000 - 1.040)
- pH @ 68°F (20°C): 6.5 - 8.0
- *Viscosity (#4 @ 30 rpm cP): 3000 - 5000
- *Viscosity (#4 @ 60 rpm cP): 1700 - 2850
- Freezing Point: 16°F (-8.9°C)
- Lowest Temperature for Use: 35°F (1.7°C)
*Brookfield DV Viscometer
Foam Properties:
- Dilution Rate: 3%
- Low Expansion Foam (UNI-86)
- Foam Expansion Index
- Drain Time: >30 minutes
Certifications:
- UL 162 Listed
- FM 5130 Approved
- Tested and certified to ICAO Level B - high performance on aviation fuels
| Size | UL Range (GPM) | FM Range (GPM) |
| 2" | 52-255 | 72-244 |
| 2.5" | 155-470 | - |
| 3" | 210-570 | 146-612 |
| 4" | 430-1370 | 475-1387 |
| 6" | 877-2893 | 770-2610 |
| 6" VRP | 35-2750* | 110-1018* |
| 8" | 2324-5001 | 2499-4403 |
| 8" VRP | 56-4112* | 60-3850* (Pending) |
*Variable Range
Cautions:
Foams should not be used in contact with electrical equipment or with chemical products that can react with water. It is recommended to avoid contact of the foam concentrate with skin. In case of eye splashes, wash with plenty of water. In case of ingestion do not induce vomiting, drink water and seek medical advice.